Qwen3-8B Quantization Comparison Summary

F16 Baseline Reference

Metric Value
F16 Perplexity 10.1114
File Size 15.26 GiB (16.00 BPW)

All precision loss percentages below are calculated relative to this F16 baseline.


Q4_K_HIFI (INT8 Residuals + Per-Block Scale)

Pros:

  • 🎯 Uses intelligent outlier preservation with INT8 residuals on critical tensors
  • 🔬 10 tensors use Q6_K_HIFI_RES8 format for maximum precision on sensitive weights
  • Best perplexity at 10.4133 (beats Q4_K_M's 10.4239)
  • Best imatrix perplexity at 10.2225 (beats Q4_K_M's 10.2355)
  • 📊 +3.0% PPL vs F16 without imatrix, +1.1% with imatrix

Cons:

  • 💾 Larger file size at 4.93 GiB (+5.3% vs Q4_K_M)
  • 🐢 Slower than Q4_K_M (117.53 vs 118.70 TPS, 1.0% slower)
  • 🐢 Slower than Q4_K_S (117.53 vs 123.04 TPS, 4.5% slower)

Best for: Maximum quality at Q4-level efficiency. Ideal when perplexity matters most.

Performance Comparison (Q4_K_HIFI vs the others)

Q4_K_M

Metric Q4_K_HIFI Q4_K_M Difference
Speed (TPS) 117.53 118.70 -1.17 (1.0% slower)
Perplexity 10.4133 10.4239 -0.01 (0.1% better)
PPL vs F16 +3.0% +3.1% 0.1% less precision loss
File Size 4.93 GiB 4.68 GiB +0.25 GiB (5.3% larger)
Bits Per Weight 5.17 4.90 +0.27 (5.5% more)

Pros:

  • ⚖️ Traditional "balanced" approach between speed and quality
  • 📚 Well-documented, standard quantization method
  • 💾 Smaller file size than Q4_K_HIFI
  • Slightly faster than Q4_K_HIFI (1.0%)
  • 📊 +3.1% PPL vs F16 — similar precision loss to Q4_K_HIFI

Cons:

  • Worse perplexity than Q4_K_HIFI (10.4239 vs 10.4133)

Best for: When speed and size are prioritized over marginal quality gains. Summary: Q4_K_HIFI delivers better quality (0.1% lower perplexity) at the cost of 5.3% larger file size and 1.0% slower inference.

Q4_K_S

Metric Q4_K_HIFI Q4_K_S Difference
Speed (TPS) 117.53 123.04 -5.51 (4.5% slower)
Perplexity 10.4133 10.6837 -0.27 (2.5% better)
PPL vs F16 +3.0% +5.7% 2.7% less precision loss
File Size 4.93 GiB 4.47 GiB +0.46 GiB (10.3% larger)
Bits Per Weight 5.17 4.68 +0.49 (10.5% more)

Pros:

  • Fastest inference at 123.04 TPS (4.5% faster than Q4_K_HIFI)
  • 💾 Smallest file size at 4.47 GiB
  • Best choice when speed and storage are critical

Cons:

  • Significantly worse quality with perplexity of 10.68 (2.5% higher than Q4_K_HIFI)
  • 📊 +5.7% PPL vs F16 — highest precision loss of Q4_K variants
  • ⚠️ Uses minimal q6_K enhancement — impacts quality on sensitive weights

Best for: Extreme resource constraints, quick prototyping, or bulk processing where quality is less important. Summary: Q4_K_HIFI trades a 4.5% speed reduction and 10.3% larger file size for a 2.5% improvement in quality over Q4_K_S.


Recommendation Matrix

Priority Recommended Model Rationale
Quality First Q4_K_HIFI Best perplexity (10.4133) without imatrix, (10.2225) with imatrix
Speed First Q4_K_S 4.5% faster than Q4_K_HIFI, acceptable if quality degradation is tolerable
Best Balance Q4_K_HIFI Best quality with acceptable speed/size overhead
Smallest Size Q4_K_S 10.3% smaller than Q4_K_HIFI, 4.5% smaller than Q4_K_M

Key Insight

At 8B scale, Q4_K_HIFI outperforms Q4_K_M with Q6_K_HIFI_RES8 enhancement:

  • 0.1% lower perplexity than Q4_K_M (10.4133 vs 10.4239)
  • 5.3% larger file size (4.93 GiB vs 4.68 GiB)
  • 1.0% slower than Q4_K_M (117.53 vs 118.70 TPS)
  • All variants lose only 3.0-5.7% precision vs F16 (10.11 baseline) — excellent retention!

The Q6_K_HIFI_RES8 format (upgraded from Q5_K_HIFI_RES8) provides the precision needed at 8B scale. The INT8 residuals with 6-bit base quantization capture weight distributions that Q4_K_M's standard q6_K enhancement misses.

💡 Scale Effect: At 8B scale, models benefit from higher-precision HIFI enhancement. The Q6_K base (vs Q5_K) in the HIFI format provides the extra headroom needed for accurate outlier representation.


Precision Loss Summary (vs F16 Baseline: PPL 10.1114)

Model PPL (no imatrix) vs F16 PPL (imatrix) vs F16
Q4_K_HIFI 10.4133 +3.0% 10.2225 +1.1%
Q4_K_M 10.4239 +3.1% 10.2355 +1.2%
Q4_K_S 10.6837 +5.7% 10.2943 +1.8%

Key Observations:

  • Without imatrix: Q4_K variants lose only 3.0-5.7% precision vs F16 — excellent retention at 8B scale
  • With imatrix: Precision loss drops to just 1.1-1.8% — nearly F16 quality!
  • Q4_K_HIFI (imatrix) achieves the lowest precision loss at only +1.1% vs F16
  • The 8B model shows the best precision retention across all model sizes tested

Tensor Distribution

Model q4_K q5_K q6_K Q6_K_HIFI_RES8 f32 Total
Q4_K_S 245 8 1 0 145 399
Q4_K_M 217 0 37 0 145 399
Q4_K_HIFI 213 0 31 10 145 399

Q4_K_HIFI Enhancement: 10 critical tensors use Q6_K_HIFI_RES8 format with INT8 residuals + per-block scale (upgraded from Q5_K_HIFI_RES8 for 8B+ models).


Addendum: Impact of imatrix on Q4_K_M and Q4_K_S

When all models are quantized with an importance matrix (imatrix), quality improves significantly across all variants.

imatrix Perplexity Improvements

Model Without imatrix With imatrix Improvement PPL vs F16 (imatrix)
Q4_K_HIFI 10.4133 10.2225 -0.191 (1.8% better) +1.1%
Q4_K_M 10.4239 10.2355 -0.188 (1.8% better) +1.2%
Q4_K_S 10.6837 10.2943 -0.389 (3.6% better) +1.8%

Revised Comparison (All with imatrix)

Model PPL (imatrix) vs Q4_K_HIFI vs F16 Size
Q4_K_HIFI 10.2225 baseline +1.1% 4.93 GiB
Q4_K_M 10.2355 +0.013 (+0.1%) +1.2% 4.68 GiB
Q4_K_S 10.2943 +0.072 (+0.7%) +1.8% 4.47 GiB

Key Findings

Q4_K_HIFI is the best choice with imatrix:

Comparison Without imatrix With imatrix
Q4_K_HIFI vs Q4_K_M -0.1% (Q4_K_HIFI better) -0.1% (Q4_K_HIFI better)
Q4_K_HIFI vs Q4_K_S -2.5% (Q4_K_HIFI better) -0.7% (Q4_K_HIFI better)

Revised Recommendations (When Using imatrix)

Priority Without imatrix With imatrix
Quality First Q4_K_HIFI Q4_K_HIFI (best perplexity)
Best Balance Q4_K_HIFI Q4_K_HIFI
Size/Speed Q4_K_S Q4_K_S

Conclusion

For both imatrix and non-imatrix quantization:

  • Q4_K_HIFI consistently outperforms Q4_K_M in perplexity (10.2225 vs 10.2355 with imatrix, 10.4133 vs 10.4239 without)
  • Q4_K_HIFI is 5.3% larger than Q4_K_M (4.93 GiB vs 4.68 GiB)
  • Q4_K_HIFI + imatrix offers the best quality with acceptable size/speed tradeoffs

Q4_K_HIFI advantages:

  • Best perplexity in all scenarios (with and without imatrix)
  • Q6_K_HIFI_RES8 format captures weight outliers that standard quantization misses
  • Significantly better quality than Q4_K_S (2.5% without imatrix, 0.7% with imatrix)

Appendix (Test Environment Details)

Component Specification
OS Ubuntu 24.04.3 LTS
CPU AMD EPYC 9254 24-Core Processor
CPU Cores 96 cores (2 threads/core)
RAM 1.0Ti
GPU NVIDIA L40S × 2
VRAM 46068 MiB per GPU
CUDA 12.9
Test Data wikitext-2-raw, 584 chunks
Context 512 tokens
Samples 100 per speed benchmark
imatrix mixed-imatrix-dataset.txt, 4697 chunks